Panduit Q1N2B1L2N30AHA0 User Manual

Browse online or download User Manual for Power distribution units (PDUs) Panduit Q1N2B1L2N30AHA0. Panduit Q1N2B1L2N30AHA0 power distribution unit PDU

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - MSeries Rack PDU

Release 1.0Issue 1.0SmartZone™ Network-EnabledMSeries Rack PDUUser Manual

Page 2

Network-Enabled M Series Rack PDU User Manual- 10 -Pre-InstallationThe Rack PDU products covered by this guide are designed to be installed within EIA

Page 3 - Table of Contents

Network-Enabled M Series Rack PDU User Manual- 11 -InstallationBefore You BeginBefore installing your PDU, refer to the following lists to ensure that

Page 4

Network-Enabled M Series Rack PDU User Manual- 12 -3. Ensure conductors are stripped adequately, exposing 15mm of copper.4. Conductors shall be connec

Page 5 - Rack PDU

Network-Enabled M Series Rack PDU User Manual- 13 -Gland Size Grommet Cap TorqueM16 1.5 N-m (13 in-lb.)M20 3.0 N-m (27 in-lb.)M254.0 N-m (35 in-lb.)M3

Page 6 - Symbol Description

Network-Enabled M Series Rack PDU User Manual- 14 -Optional AccessoriesSmartZone Environmental Sensors:l Smoke Sensorl Humidity Sensorl Water Rope Sen

Page 7 - Equipment Overview

Network-Enabled M Series Rack PDU User Manual- 15 -Warning: For permanently connected equipment, a readily accessible disconnectdevice should be incor

Page 8 - Model Numbers

Network-Enabled M Series Rack PDU User Manual- 16 -accordance with the instruction manual, may cause harmful interference to radio com-munications. Op

Page 9

Network-Enabled M Series Rack PDU User Manual- 17 -MountingThere are two mounting options for Rack RDUsl Vertical Mountingl Horizontal MountingInstruc

Page 10 - Pre-Installation

Network-Enabled M Series Rack PDU User Manual- 18 -

Page 11 - Installation

Network-Enabled M Series Rack PDU User Manual- 19 -PDU Bracket for 4-Post Racks

Page 12

Network-Enabled M Series Rack PDU User Manual- 2 -Copyright © 2014 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored

Page 13 - Gland Size Grommet Cap Torque

Network-Enabled M Series Rack PDU User Manual- 20 -PDU Bracket for 2-Post Racks

Page 14 - Safety Precautions

Network-Enabled M Series Rack PDU User Manual- 21 -Horizontal MountingThis product is intended to be installed using the rack's RU mountings via

Page 15

Network-Enabled M Series Rack PDU User Manual- 22 -HardwareLCD DisplayThe display shows the firmware version number, device model number, serial numbe

Page 16 - Environmental Specifications

Network-Enabled M Series Rack PDU User Manual- 23 -Mode Button OperationBootloader StartupWhen the user presses and holds the Mode button, the Display

Page 17 - Mounting

Network-Enabled M Series Rack PDU User Manual- 24 -The application stays in this mode for at least 5 seconds. If no button operation is detec-ted, the

Page 18

Network-Enabled M Series Rack PDU User Manual- 25 -Graphical User InterfaceThe Panduit Network Enabled Rack PDU provides access to configuration, powe

Page 19 - PDU Bracket for 4-Post Racks

Network-Enabled M Series Rack PDU User Manual- 26 -The default login and password are:Login:adminPassword:adminAfter successful login, the GUI opens t

Page 20 - PDU Bracket for 2-Post Racks

Network-Enabled M Series Rack PDU User Manual- 27 -There are three modules within the GUI, each providing access to a different area withinthe PDU. Th

Page 21 - Horizontal Mounting

Network-Enabled M Series Rack PDU User Manual- 28 -SetupWhen the setup module is selected, the following menu items appear along the left handside of

Page 22 - Hardware

Network-Enabled M Series Rack PDU User Manual- 29 -IP ConfigurationSystem Name The name of the PDUSystem Location The location of the PDUContact Name

Page 23 - Mode Button Operation

Network-Enabled M Series Rack PDU User Manual- 3 -Table of ContentsSmartZone™ Network-Enabled MSeries Rack PDU 5Contacting Panduit 5Symbols Used 5Equ

Page 24 - Internal Error Notification

Network-Enabled M Series Rack PDU User Manual- 30 -The DHCP configuration (Dynamic Addressing provided by Infrastructure)l The DHCPv4 client allows th

Page 25 - Graphical User Interface

Network-Enabled M Series Rack PDU User Manual- 31 -DHCPv6 configuration (dynamic addressing provided by infrastructure)The DHCPv6 client allows the us

Page 26

Network-Enabled M Series Rack PDU User Manual- 32 -To choose the access method, click the corresponding radio button and enter the appro-priate Port n

Page 27

Network-Enabled M Series Rack PDU User Manual- 33 -Both SNMPv2c and SNMPv3 protocols are supported simultaneously. You must enterthe credential infor

Page 28 - IP Config

Network-Enabled M Series Rack PDU User Manual- 34 -Access Permission SettingsRead Only Permits the NMS to use only GET commandsRead / WritePermits the

Page 29 - IPv4 Address Configuration

Network-Enabled M Series Rack PDU User Manual- 35 -Receive Traps Settingsrange of trapsEnabled (Incl. Auth Fails)Receive traps – causes the unit to is

Page 30 - IPv6 Address Configuration

Network-Enabled M Series Rack PDU User Manual- 36 -SNMP Trap Text FormatOn, Information Off, Cleared, Unknown.<source-name> ::= <text> Dat

Page 31

Network-Enabled M Series Rack PDU User Manual- 37 -The PDU GUI comes with the Administrator login predefined as:l Login:adminl Password:adminTo add ne

Page 32 - SNMP NMS

Network-Enabled M Series Rack PDU User Manual- 38 -Email AlertsOn this page, you can edit email alert settings for traps. You may set up to 10 emailre

Page 33

Network-Enabled M Series Rack PDU User Manual- 39 -Time SettingsThe Time Settings page allows you to view or edit the current date and time.Select the

Page 34 - SNMP Receivers

Network-Enabled M Series Rack PDU User Manual- 4 -IPv4 Address Configuration 29The DHCP configuration (Dynamic Addressing provided by Infrastructure)

Page 35

Network-Enabled M Series Rack PDU User Manual- 40 -l SNTP Servers - Simple Network Time Protocol synchronizes the clocks of com-puter systems over a n

Page 36

Network-Enabled M Series Rack PDU User Manual- 41 -EventsThe View Events page shows a history of events that have occurred, along with specificdetails

Page 37

Network-Enabled M Series Rack PDU User Manual- 42 -PreferencesDefault PageFrom the dropdown menu, select the first page you wantto open when a user lo

Page 38 - Email Alerts

Network-Enabled M Series Rack PDU User Manual- 43 -RestartClicking the Restart option brings up the following screen:To restart the unit or restore to

Page 39 - Time Settings

Network-Enabled M Series Rack PDU User Manual- 44 -Input SensorsWhen the Input Sensors module is selected, the following items appear along the left-h

Page 40 - Syslog Servers

Network-Enabled M Series Rack PDU User Manual- 45 -Status IndicatorsAll thresholds within limitsUpper Control Limit reached/exceededUpper Warning Limi

Page 41 - Preferences

Network-Enabled M Series Rack PDU User Manual- 46 -The Humidity Sensors screen displays default information as shown below.The Analog Voltage screen d

Page 42

Network-Enabled M Series Rack PDU User Manual- 47 -Explanations of the editable fields in the drop-down menus for Temperature, Humidityand Analog Volt

Page 43

Network-Enabled M Series Rack PDU User Manual- 48 -Defaults- Temperature, Humidity, and Analog Voltageand alarm purposes would be 42. This works in an

Page 44 - Input Sensors

Network-Enabled M Series Rack PDU User Manual- 49 -Defaults- Open/Close ContactsNormal StateNormal state specifies the condition in which a contact is

Page 45 - Defaults

Network-Enabled M Series Rack PDU User Manual- 5 -SmartZone™ Network-Enabled MSeriesRack PDUNetwork-Enabled M(Monitored)Series Rack PDUs integrate

Page 46

Network-Enabled M Series Rack PDU User Manual- 50 -Defaults- Open/Close Contactsan alarm is required to persist after an input changes fromthe Normal

Page 47

Network-Enabled M Series Rack PDU User Manual- 51 -Individual settings can be entered for each input channel. The drop-down menu optionsare identical

Page 48

Network-Enabled M Series Rack PDU User Manual- 52 -Enter text to be displayed for each type of trap.

Page 49

Network-Enabled M Series Rack PDU User Manual- 53 -PowerWhen the Power module is selected, the following menu items appear along the left-hand side of

Page 50 - Configure

Network-Enabled M Series Rack PDU User Manual- 54 -Status 3-PhaseIf the device is 3-Phase, you will see the 3-Phase Status button as shown below. The

Page 51 - Sensor Trap Text

Network-Enabled M Series Rack PDU User Manual- 55 -ConfigureThe Configure page allows you to view and configure Power Circuits. Depending onthe type o

Page 52

Network-Enabled M Series Rack PDU User Manual- 56 -Clicking on the arrows next to each option opens a drop-down similar to the following:Explanations

Page 53 - Branch Monitoring

Network-Enabled M Series Rack PDU User Manual- 57 -Configure Power CircuitsCircuit Name The name of the chosen circuit.Upper Control Limit The value a

Page 54 - Thresholds

Network-Enabled M Series Rack PDU User Manual- 58 -Enter the desired text in the text box provided, and click the Save button to implementyour customi

Page 55

Network-Enabled M Series Rack PDU User Manual- 6 -Symbol Description| ONO OFF

Page 56

Network-Enabled M Series Rack PDU User Manual- 7 -Equipment OverviewThe power inlet/cord(s) connects the PDU to the electrical power source. On metere

Page 57

Network-Enabled M Series Rack PDU User Manual- 8 -Letter What It RepresentsE Any numeral, 1-7, indicating the number of output circuit breakersFAny le

Page 58

Network-Enabled M Series Rack PDU User Manual- 9 -Part NumberQ1N1B3H0A30AHA0Q1N1B3H0A30AXA0Q1N2B1J0A30AHA0Q1N2B1L2N30AHA0Q1N2B1M2M24AKA0Q1N2B1N3N30AHA

Comments to this Manuals